This system is a digital optic transmission system applicable to the IMT-2000 system that can be applied to solve a shaded region and coverage expansion. The application of digital signal processing and transmission method provides little deterioration of signal quality caused by transmission loss, and provides greater transmission range and multiple-center method as well as selective FA transmission compared to the existing analog forms, which allows flexible network design and efficient telephone traffic.
1) Reliability among the transmission areas through the maintenance of S/N ratio with
     the digital optic transmission of MHU and ROU
2) Consistent gain independent of the distance between MHU and ROU, which provides
     convenience in installation and repairs.
3) Control for correcting line damage is unnecessary.
4) Formation of an effective network allows long-distance transmission, which provides
    an effective solution for shaded areas.
5) The ROU output is 40W (46dBm), which makes it applicable even in regions that
     require a cascade.
6) The use of a simple optic cable, which allows the connection of a maximum of 12
     ROU. Divergence from ROU and MHU is possible, and cost is reduced compared to
     the use of multiple cables.
1) WCDMA (3G) service
2) Solution of outdoors shaded areas
3) Digital optic transmission system service
 

Items

Performance Requirements

Notes

Frequency Range

Front Direction

2150 ~ 2170 MHz

Opposite Direction

1960 ~ 1980 MHz

Occupied Band Width(OBW)

Less than5MHz/FA

99% Channel Power

Main Frequency Used
(Front Direction)

1FA : 2152.6 MHz
2FA : 2157.4 MHz
3FA : 2162.4 MHz
4FA : 2167.2 MHz

Main Frequency Used
(Opposite Direction)

1FA : 1962.6 MHz
2FA : 1967.4 MHz
3FA : 1972.4 MHz
4FA : 1977.2 MHz

Range Evenness

3dB within

Peak to Peak

Frequency Stability

± 0.03 ppm or less

Test Model 3
32DPCH

Gain Control Interval

Front Direction

40W

46 ~ 76dB

20W

43 ~ 73dB

15W

42 ~ 72dB

Opposite Direction

40 ~ 60dB

Gain Control Interval

1dB/Step or less

Gain Control Error

Step : ±0.7dB

All sections

Input Level

Front Direction

- 30 ~ 0 dBm

4FA standard

Opposite Direction

- 120 ~ - 65 dBm

Output Level

Front Direction

+46 dBm/Total(40W)

4FA standard

+43 dBm/Total(20W)

+42 dBm/Total(15W)

Opposite Direction

- 5 dBm or greater

Transmission/Reception Segregation Rate

110 dBc or greater

Input/Output Standing Wave Ratio

1.5 : 1 or less

IN/OUT Connector TYPE

MHU : SMA Female

ROU : N Female

System Time Delay

5us or less

Excluding Optical Link Delay

Spurious Radioactive Feature (outside the range)

9KHz ~ 800 MHz

-13 dBm or less

RBW    1KHz

800 ~ 1870 MHz

RBW    10KHz

2300 ~ 2400 MHz

RBW    100KHz

1GHz ~12,75GHz

RBW    1MHz

Delay Control

Control Range

Maximum 80us

ROU

Control Interval

2us

Control Error

1us

Switching Time

Feature Check

ROU

Front Direction Items

Error Vector Magnitude (EVM)

12.5 % or less

Test Model 1,4
64 DPCH,
Test Model 5
30 DPCH

Peak Code Domain Error (PCDE)

- 35 dB or less

Test Model 3
32 DPCH
SF = 256시

Output Loading Control Feature

Setting Range

40W

+40 ~ +47dBm

@ 4FA

20W

+37 ~ +44dBm

20W

+36 ~ +43dBm

Setting Error

±1.5 dB

Spurious Radioactive Feature

40W

+/-2.5MHz

- 14 dBm or less

@ Maximum Output
RBW 30KHz

+/-3.5MHz

- 26 dBm or less

+/-4.0MHz

- 13 dBm or less

@ Maximum Output
RBW 1MHz

+/-8.0MHz

- 16 dBm or less

ACLR

5MHz

45 dBc or greater

@ Maximum Output
RBW 30KHz

10MHz

50 dBc or greater

Interference of Other Firms

@2147.4MHz

-13 dBm or less/ 3.84MHz

@ Maximum Output
RBW 30KHz

2ndHarmonicRejection

80 dBc or greater

Monitoring Port (Directional Coupler)

40 dB ±1dB

SMA TYPE

Opposite Direction Items

3rdOrderInterceptPoint(IP3)

+ 20dBm or greater

-65 dBm,    2 CW @ Maximum Gain

System Noise Factor (NF)

5 dB  or less

@ Maximum Benefit
Optical Loss
@ 10dBo (30Km)

Rx0 - Rx1 - Isolation

50 dBc or greater

Output Loading Control Feature

Setting Range

-11 ~ -4dBm

@ 4FA

 
D-FORCE MHU Right Panel-Top MHU F
D-FORCE MHU Right Panel-Top D-FORCE MHU Front Panel
D-FORCE MHU Right-Back Panel D-FORCE MHU Back Panel
D-FORCE MHU Right-Back Panel D-FORCE MHU Back Panel
D-FORCE ROU Front Panel
D-FORCE ROU Front Panel D-FORCE ROU-Interior
  send inquiry mail